T1 - Application of a new vitamin D blood test on the Emirati population
AU - shah, Iltaf
AU - Al-Dabbagh, Bayan
AU - Gariballa, Salah
AU - Al-Menhali, Asma
AU - Muhammad, Neak
AU - Yasin, Javed
AU - Ashraf, S. Salman
N1 - Funding Information:
The authors would like to graciously acknowledge the generous funding from the United Arab Emirates University (UAEU) , from Iltaf Shah (Start Up Research Funding Grant #31S213 ), and from Bayan Al-Dabbagh (Start Up Research Funding Grant #31S215 ). We are also thankful to Dr. Salah Gariballa for providing samples for this study.
Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/6
Y1 - 2018/6
N2 - Research shows that immunoassay techniques are not the best choice for the estimation of vitamin D in human blood samples. The main reasons are that some immunoassays are not able to distinguish between 25-OHD3 and 25-OHD2 vitamin D metabolites. Furthermore, immunoassays cannot differentiate between 25OHD and inactive epimers of vitamin D. Vitamin D epimers and isobars have been known to overlap with the 25OHD signals and give false positives when tested. Liquid chromatography tandem-mass spectrometry (LC–MS/MS) can differentiate between 25OHD3 and 25OHD2. Separating epimers and isobars (which have the same molecular weight) from vitamin D is achieved through chromatographic separation from actual 25OHD peaks, although this could also cause inaccuracies in vitamin D measurements. The main aim of this study was to develop and validate an improved LC–MS/MS method (using a Shimadzu 8060 system) that could accurately detect and quantitate up to 10 different metabolites of vitamin D, as well as differentiate the epimers and isobars. The secondary aim was to apply the developed LC–MS/MS method for the accurate measurement of blood vitamin D levels in the Emirati population. The Shimadzu 8060 system was run using positive ion electrospray ionization (ESI) in Dynamic Multiple Reaction Monitoring (DMRM) mode for quantification. The method involved blood sample collection from 80 Emirati volunteers, followed by serum extraction and liquid–liquid extraction. The chromatography column used for the analysis was an Ascentis Express F5. Precursor and product ions were detected using a Shimadzu 8060 LC–MS/MS system, and 10 metabolites of vitamin D were detected and quantified, including epimers and isobars. The method validation showed good sensitivity, recovery, linearity, precision, specificity, and accuracy. Furthermore, the data showed that vitamin D epimer 3-epi-25OHD and isobar 7-α-hydroxy-4-cholesten-3-one (7αC4) accounted for a significant portion of vitamin D results in the Emirati population. We report a more reliable, reproducible, and robust LC–MS/MS method for the accurate detection of 25OHD (vitamin D) in the Emirati population. The method has the capacity to detect and separate 10 metabolites of vitamin D as well as separate 25OHD from co-eluting epimers and isobars. The method has also been successfully implemented in gauging vitamin D deficiency in the Emirati population. Thus, this improved LC–MS/MS method could prove very useful in accurately estimating the levels of vitamin D in the Emirati population and in further clinical studies.
AB - Research shows that immunoassay techniques are not the best choice for the estimation of vitamin D in human blood samples. The main reasons are that some immunoassays are not able to distinguish between 25-OHD3 and 25-OHD2 vitamin D metabolites. Furthermore, immunoassays cannot differentiate between 25OHD and inactive epimers of vitamin D. Vitamin D epimers and isobars have been known to overlap with the 25OHD signals and give false positives when tested. Liquid chromatography tandem-mass spectrometry (LC–MS/MS) can differentiate between 25OHD3 and 25OHD2. Separating epimers and isobars (which have the same molecular weight) from vitamin D is achieved through chromatographic separation from actual 25OHD peaks, although this could also cause inaccuracies in vitamin D measurements. The main aim of this study was to develop and validate an improved LC–MS/MS method (using a Shimadzu 8060 system) that could accurately detect and quantitate up to 10 different metabolites of vitamin D, as well as differentiate the epimers and isobars. The secondary aim was to apply the developed LC–MS/MS method for the accurate measurement of blood vitamin D levels in the Emirati population. The Shimadzu 8060 system was run using positive ion electrospray ionization (ESI) in Dynamic Multiple Reaction Monitoring (DMRM) mode for quantification. The method involved blood sample collection from 80 Emirati volunteers, followed by serum extraction and liquid–liquid extraction. The chromatography column used for the analysis was an Ascentis Express F5. Precursor and product ions were detected using a Shimadzu 8060 LC–MS/MS system, and 10 metabolites of vitamin D were detected and quantified, including epimers and isobars. The method validation showed good sensitivity, recovery, linearity, precision, specificity, and accuracy. Furthermore, the data showed that vitamin D epimer 3-epi-25OHD and isobar 7-α-hydroxy-4-cholesten-3-one (7αC4) accounted for a significant portion of vitamin D results in the Emirati population. We report a more reliable, reproducible, and robust LC–MS/MS method for the accurate detection of 25OHD (vitamin D) in the Emirati population. The method has the capacity to detect and separate 10 metabolites of vitamin D as well as separate 25OHD from co-eluting epimers and isobars. The method has also been successfully implemented in gauging vitamin D deficiency in the Emirati population. Thus, this improved LC–MS/MS method could prove very useful in accurately estimating the levels of vitamin D in the Emirati population and in further clinical studies.
KW - Emirati population
KW - Epimers
KW - Isobars
KW - LC–MS/MS
KW - Vitamin D
KW - Vitamin D blood test
UR - http://www.scopus.com/inward/record.url?scp=85042029051&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85042029051&partnerID=8YFLogxK
U2 - 10.1016/j.jsbmb.2018.02.003
DO - 10.1016/j.jsbmb.2018.02.003
M3 - Article
C2 - 29432962
AN - SCOPUS:85042029051
SN - 0960-0760
VL - 180
SP - 118
EP - 128
JO - Journal of Steroid Biochemistry and Molecular Biology
JF - Journal of Steroid Biochemistry and Molecular Biology
ER -