TY - JOUR
T1 - Cost-effective and sustainable heating solutions for indoor swimming pools
T2 - A comparative study and LCOH assessment of PV-heat pumps and solar thermal collectors
AU - Mardi, Mohamed El
AU - Allouhi, Amine
AU - Rami, Yassine
AU - Tabet Aoul, Kheira Anissa
N1 - Publisher Copyright:
© 2025 The Authors
PY - 2025/6
Y1 - 2025/6
N2 - This study presents a comprehensive technoeconomic analysis of three water heat system configurations to satisfy the heating requirements of an indoor swimming pool in Fez, Morocco. The assessed configurations included a flat-plate solar collector with a diesel boiler backup, evacuated-tube collector with a diesel boiler backup, and grid-connected photovoltaic (PV) plant combined with a heat pump. The analysis emphasizes multicriteria evaluation and sensitivity analyses as distinguishing features. The analytical results demonstrated that the configuration with a grid-connected PV plant combined with a heat pump outperformed the other configurations in terms of economic viability. This configuration exhibited a short payback period of 4.415 years, indicating a rapid return on investment. The levelized cost of heating (LCOH) for this configuration was 0.0258 $/kWh, highlighting its cost-effectiveness. However, this configuration allowed avoiding CO2 emissions up to 35.63 tons/year, which is considerably lower than solar thermal heating systems. Sensitivity analyses revealed that the coefficient of performance (COP), diesel cost, and collector/panel cost were critical factors influencing the performance and economic feasibility of the compared systems. Optimizing the COP and efficiency of heating systems, combined with lower technology costs, can significantly improve the payback period, reduce the levelized cost of heat (LCOH), and enhance CO₂ emissions mitigation. Expanding the analysis to other Moroccan cities helped identify optimal locations for solar heating systems.
AB - This study presents a comprehensive technoeconomic analysis of three water heat system configurations to satisfy the heating requirements of an indoor swimming pool in Fez, Morocco. The assessed configurations included a flat-plate solar collector with a diesel boiler backup, evacuated-tube collector with a diesel boiler backup, and grid-connected photovoltaic (PV) plant combined with a heat pump. The analysis emphasizes multicriteria evaluation and sensitivity analyses as distinguishing features. The analytical results demonstrated that the configuration with a grid-connected PV plant combined with a heat pump outperformed the other configurations in terms of economic viability. This configuration exhibited a short payback period of 4.415 years, indicating a rapid return on investment. The levelized cost of heating (LCOH) for this configuration was 0.0258 $/kWh, highlighting its cost-effectiveness. However, this configuration allowed avoiding CO2 emissions up to 35.63 tons/year, which is considerably lower than solar thermal heating systems. Sensitivity analyses revealed that the coefficient of performance (COP), diesel cost, and collector/panel cost were critical factors influencing the performance and economic feasibility of the compared systems. Optimizing the COP and efficiency of heating systems, combined with lower technology costs, can significantly improve the payback period, reduce the levelized cost of heat (LCOH), and enhance CO₂ emissions mitigation. Expanding the analysis to other Moroccan cities helped identify optimal locations for solar heating systems.
KW - CO emissions reduction
KW - Heat pumps
KW - Levelized cost of heating
KW - Solar thermal collectors
KW - Sustainability
KW - Swimming pool
UR - https://www.scopus.com/pages/publications/105001360622
UR - https://www.scopus.com/pages/publications/105001360622#tab=citedBy
U2 - 10.1016/j.nexus.2025.100414
DO - 10.1016/j.nexus.2025.100414
M3 - Article
AN - SCOPUS:105001360622
SN - 2772-4271
VL - 18
JO - Energy Nexus
JF - Energy Nexus
M1 - 100414
ER -