TY - JOUR
T1 - Desorption electrospray ionization mass spectrometry of intact bacteria
AU - Meetani, Mohammed A.
AU - Shin, Yong Seung
AU - Zhang, Shaofeng
AU - Mayer, Richard
AU - Basile, Franco
PY - 2007/9
Y1 - 2007/9
N2 - Desorption electrospray ionization (DESI) mass spectrometry (MS) was used to differentiate seven bacteria species on the basis of their measured DESI-mass spectral profile. Both gram-positive and gram-negative bacteria were tested and included Escherichia coli, Staphyloccocus aureus, Enterococcus sp., Bordetella bronchiseptica, Bacillus thuringiensis, Bacillus subtilis and Salmonella typhimurium. Distinct DESI-mass spectra, in the mass range of 50-500 u, were obtained from whole bacteria in either positive or negative ion modes in less than 2 mins analysis time. Positive ion DESI-mass spectral fingerprints were compared using principal components analysis (PCA) to investigate reproducibility for the intraday and the day-to-day measurements and the method selectivity to differentiate the bacteria studied. Detailed study of variances in the assay revealed that a large contribution to the DESI-mass spectral fingerprint variation was the growth media preparation procedure. Specifically, experiments conducted with the growth media prepared using the same batch yielded highly reproducible DESI-mass spectra, both in intraday and in day-to-day analyses (i.e. one batch of growth media used over a 3-day period versus a new batch every day over the same 3-day period). Conclusions are drawn from our findings in terms of strategies for rapid biodetection with DESI-MS.
AB - Desorption electrospray ionization (DESI) mass spectrometry (MS) was used to differentiate seven bacteria species on the basis of their measured DESI-mass spectral profile. Both gram-positive and gram-negative bacteria were tested and included Escherichia coli, Staphyloccocus aureus, Enterococcus sp., Bordetella bronchiseptica, Bacillus thuringiensis, Bacillus subtilis and Salmonella typhimurium. Distinct DESI-mass spectra, in the mass range of 50-500 u, were obtained from whole bacteria in either positive or negative ion modes in less than 2 mins analysis time. Positive ion DESI-mass spectral fingerprints were compared using principal components analysis (PCA) to investigate reproducibility for the intraday and the day-to-day measurements and the method selectivity to differentiate the bacteria studied. Detailed study of variances in the assay revealed that a large contribution to the DESI-mass spectral fingerprint variation was the growth media preparation procedure. Specifically, experiments conducted with the growth media prepared using the same batch yielded highly reproducible DESI-mass spectra, both in intraday and in day-to-day analyses (i.e. one batch of growth media used over a 3-day period versus a new batch every day over the same 3-day period). Conclusions are drawn from our findings in terms of strategies for rapid biodetection with DESI-MS.
KW - Bacteria
KW - Biodetection
KW - Biomarkers
KW - Desorption electrospray ionization
KW - Principal components analysis
UR - http://www.scopus.com/inward/record.url?scp=34548607828&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34548607828&partnerID=8YFLogxK
U2 - 10.1002/jms.1250
DO - 10.1002/jms.1250
M3 - Article
C2 - 17628040
AN - SCOPUS:34548607828
SN - 1076-5174
VL - 42
SP - 1186
EP - 1193
JO - Journal of Mass Spectrometry
JF - Journal of Mass Spectrometry
IS - 9
ER -