T1 - Mapping slow waves and spikes in chronically instrumented conscious dogs
T2 - Implantation techniques and recordings
AU - Ver Donck, L.
AU - Lammers, W. J.E.P.
AU - Moreaux, B.
AU - Smets, D.
AU - Voeten, J.
AU - Vekemans, J.
AU - Schuurkes, J. A.J.
AU - Coulie, B.
PY - 2006/3
Y1 - 2006/3
N2 - Myoelectric recordings from the intestines in conscious animals have been limited to a few electrode sites with relatively large inter-electrode distances. The aim of this project was to increase the number of recording sites to allow high-resolution reconstruction of the propagation of myoelectrical signals. Sets of six unipolar electrodes, positioned in a 3×2 array, were constructed. A silver ring close to each set served as the reference electrodes. Inter-electrode distances varied from 4 to 8 mm. Electrode sets, to a maximum of 4, were implanted in various configurations allowing recording from 24 sites simultaneously. Four sets of 6 electrodes each were implanted successfully in 11 female Beagles. Implantation sites evaluated were the upper small intestine (n=10), the lower small intestine (n=4) and the stomach (n=3). The implants remained functional for 7.2 months (median; range 1.4-27.3 months). Recorded signals showed slow waves at regular intervals and spike potentials. In addition, when the sets were positioned close together, it was possible to re-construct the propagation of individual slow waves, to determine their direction of propagation and to calculate their propagation velocity. No signs or symptoms of interference with normal GI-function were observed in the tested animals. With this approach, it is possible to implant 24 extracellular electrodes on the serosal surface of the intestines without interfering with its normal physiology. This approach makes it possible to study the electrical activities of the GI system at high resolution in vivo in the conscious animal.
AB - Myoelectric recordings from the intestines in conscious animals have been limited to a few electrode sites with relatively large inter-electrode distances. The aim of this project was to increase the number of recording sites to allow high-resolution reconstruction of the propagation of myoelectrical signals. Sets of six unipolar electrodes, positioned in a 3×2 array, were constructed. A silver ring close to each set served as the reference electrodes. Inter-electrode distances varied from 4 to 8 mm. Electrode sets, to a maximum of 4, were implanted in various configurations allowing recording from 24 sites simultaneously. Four sets of 6 electrodes each were implanted successfully in 11 female Beagles. Implantation sites evaluated were the upper small intestine (n=10), the lower small intestine (n=4) and the stomach (n=3). The implants remained functional for 7.2 months (median; range 1.4-27.3 months). Recorded signals showed slow waves at regular intervals and spike potentials. In addition, when the sets were positioned close together, it was possible to re-construct the propagation of individual slow waves, to determine their direction of propagation and to calculate their propagation velocity. No signs or symptoms of interference with normal GI-function were observed in the tested animals. With this approach, it is possible to implant 24 extracellular electrodes on the serosal surface of the intestines without interfering with its normal physiology. This approach makes it possible to study the electrical activities of the GI system at high resolution in vivo in the conscious animal.
KW - Conscious animal
KW - Electrical mapping
KW - Gastrointestinal system
UR - http://www.scopus.com/inward/record.url?scp=33745442925&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33745442925&partnerID=8YFLogxK
U2 - 10.1007/s11517-005-0018-9
DO - 10.1007/s11517-005-0018-9
M3 - Article
C2 - 16937158
AN - SCOPUS:33745442925
SN - 0140-0118
VL - 44
SP - 170
EP - 178
JO - Medical and Biological Engineering and Computing
JF - Medical and Biological Engineering and Computing
IS - 3
ER -