T1 - Non-invasive estimation of hemoglobin, bilirubin and oxygen saturation of neonates simultaneously using whole optical spectrum analysis at point of care
AU - Banerjee, Amrita
AU - Bhattacharyya, Neha
AU - Ghosh, Ria
AU - Singh, Soumendra
AU - Adhikari, Aniruddha
AU - Mondal, Susmita
AU - Roy, Lopamudra
AU - Bajaj, Annie
AU - Ghosh, Nilanjana
AU - Bhushan, Aman
AU - Goswami, Mahasweta
AU - Ahmed, Ahmed S.A.
AU - Moussa, Ziad
AU - Mondal, Pulak
AU - Mukhopadhyay, Subhadipta
AU - Bhattacharyya, Debasis
AU - Chattopadhyay, Arpita
AU - Ahmed, Saleh A.
AU - Mallick, Asim Kumar
AU - Pal, Samir Kumar
N1 - Funding Information:
SKP thanks the Indian National Academy of Engineering (INAE) for the Abdul Kalam Technology Innovation National Fellowship, INAE/121/AKF. The authors would like to acknowledge the Deanship of Scientific Research at Umm Al-Qura University, for supporting this work by Grant code: 22UQU4320545DSR31. Dr. Ziad Moussa is grateful to the United Arab Emirates University (UAEU) and to the Research Office for supporting the research developed in his laboratory and reported herein (SUREPLUS Grant code G00003918).
Publisher Copyright:
© 2023, The Author(s).
PY - 2023/12
Y1 - 2023/12
N2 - The study was aimed to evaluate the performance of a newly developed spectroscopy-based non-invasive and noncontact device (SAMIRA) for the simultaneous measurement of hemoglobin, bilirubin and oxygen saturation as an alternative to the invasive biochemical method of blood sampling. The accuracy of the device was assessed in 4318 neonates having incidences of either anemia, jaundice, or hypoxia. Transcutaneous bilirubin, hemoglobin and blood saturation values were obtained by the newly developed instrument which was corroborated with the biochemical blood tests by expert clinicians. The instrument is trained using Artificial Neural Network Analysis to increase the acceptability of the data. The artificial intelligence incorporated within the instrument determines the disease condition of the neonate. The Pearson’s correlation coefficient, r was found to be 0.987 for hemoglobin estimation and 0.988 for bilirubin and blood gas saturation respectively. The bias and the limits of agreement for the measurement of all the three parameters were within the clinically acceptance limit.
AB - The study was aimed to evaluate the performance of a newly developed spectroscopy-based non-invasive and noncontact device (SAMIRA) for the simultaneous measurement of hemoglobin, bilirubin and oxygen saturation as an alternative to the invasive biochemical method of blood sampling. The accuracy of the device was assessed in 4318 neonates having incidences of either anemia, jaundice, or hypoxia. Transcutaneous bilirubin, hemoglobin and blood saturation values were obtained by the newly developed instrument which was corroborated with the biochemical blood tests by expert clinicians. The instrument is trained using Artificial Neural Network Analysis to increase the acceptability of the data. The artificial intelligence incorporated within the instrument determines the disease condition of the neonate. The Pearson’s correlation coefficient, r was found to be 0.987 for hemoglobin estimation and 0.988 for bilirubin and blood gas saturation respectively. The bias and the limits of agreement for the measurement of all the three parameters were within the clinically acceptance limit.
UR - http://www.scopus.com/inward/record.url?scp=85147791015&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85147791015&partnerID=8YFLogxK
U2 - 10.1038/s41598-023-29041-w
DO - 10.1038/s41598-023-29041-w
M3 - Article
C2 - 36759533
AN - SCOPUS:85147791015
SN - 2045-2322
VL - 13
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 2370
ER -