TY - JOUR
T1 - Preparation and evaluation of new uranyl imprinted polymer electrode sensor for uranyl ion based on uranyl-carboxybezotriazole complex in pvc matrix membrane
AU - Abu-Dalo, Muna A.
AU - Al-Rawashdeh, Nathir A.F.
AU - Al-Mheidat, Ismaeel R.
AU - Nassory, Nabil S.
N1 - Funding Information:
The authors are grateful to Jordan University of Science and Technology (JUST) for the financial support and to the Scholar Rescue Fund (SRF), Iraq for sponsoring the research visit of Professor Nabil S. Nassory.
Publisher Copyright:
© 2016 Published by Elsevier B.V.
PY - 2016/5/1
Y1 - 2016/5/1
N2 - In this study a new uranyl selective electrochemical sensors were prepared by using uranyl ionic imprinted polymer (IIP). The IIP was prepared by thermal polymerization using acrylic acid as a monomer, ethylene glycol dimethacrylate (EGDMA) as a cross linking and a benzoyl peroxide (BPO) as an initiator. Uranyl-carboxybenzotriazol (UO2-CBT) complex was used as an active material on the prepared polymer. Several uranyl electrodes were constructed by using different masses of polyvinyl chloride (PVC) matrix. Electrode parameters including slopes, working concentrations, pH, and interferences were evaluated. The electrodes exhibit a Nernstian response with slopes of 23.6 and 28.1 mV/decade for graphite uranyl electrode and liquid uranyl electrode, respectively, over a wide range of concentration from 3 × 10-6 to 6 × 10-2 M and a detection limit of 1 × 10-6 M. It can be used in the pH range of 4.3-10.5 with a response time of less than 60 s. The effect of ions interferences (such as: Cr3+, La3+, Ba2+, Ca2+, Cu2+, Na+, and K+) on the electrode response were evaluated. The IIP and nonimprinted polymer (NIP) membranes were characterized by Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron microscopy (SEM). The binding capacity and equilibrium dissociation constant were determined by studying the binding isotherm. The concentrations of uranyl ion in the prepared synthetic solutions determined by the standard addition method and the results were satisfactory with errors less than 7%. Finally, the prepared graphite UO2-IIP sensor was tested to determine the uranyl ions concentrations in a real environmental water sample by standard addition method. The results were compared with those obtained by spectrophotometric method which showed a good agreement. The developed electrode was found to be fast, sensitive and reliable indicated its potential use in measuring the uranly ion concentration in the field.
AB - In this study a new uranyl selective electrochemical sensors were prepared by using uranyl ionic imprinted polymer (IIP). The IIP was prepared by thermal polymerization using acrylic acid as a monomer, ethylene glycol dimethacrylate (EGDMA) as a cross linking and a benzoyl peroxide (BPO) as an initiator. Uranyl-carboxybenzotriazol (UO2-CBT) complex was used as an active material on the prepared polymer. Several uranyl electrodes were constructed by using different masses of polyvinyl chloride (PVC) matrix. Electrode parameters including slopes, working concentrations, pH, and interferences were evaluated. The electrodes exhibit a Nernstian response with slopes of 23.6 and 28.1 mV/decade for graphite uranyl electrode and liquid uranyl electrode, respectively, over a wide range of concentration from 3 × 10-6 to 6 × 10-2 M and a detection limit of 1 × 10-6 M. It can be used in the pH range of 4.3-10.5 with a response time of less than 60 s. The effect of ions interferences (such as: Cr3+, La3+, Ba2+, Ca2+, Cu2+, Na+, and K+) on the electrode response were evaluated. The IIP and nonimprinted polymer (NIP) membranes were characterized by Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron microscopy (SEM). The binding capacity and equilibrium dissociation constant were determined by studying the binding isotherm. The concentrations of uranyl ion in the prepared synthetic solutions determined by the standard addition method and the results were satisfactory with errors less than 7%. Finally, the prepared graphite UO2-IIP sensor was tested to determine the uranyl ions concentrations in a real environmental water sample by standard addition method. The results were compared with those obtained by spectrophotometric method which showed a good agreement. The developed electrode was found to be fast, sensitive and reliable indicated its potential use in measuring the uranly ion concentration in the field.
KW - Acrylic acid
KW - Carboxy benzothriazole
KW - Ionic imprinted polymer
KW - Uranyl sensor
UR - http://www.scopus.com/inward/record.url?scp=84952802104&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84952802104&partnerID=8YFLogxK
U2 - 10.1016/j.snb.2015.12.076
DO - 10.1016/j.snb.2015.12.076
M3 - Article
AN - SCOPUS:84952802104
SN - 0925-4005
VL - 227
SP - 336
EP - 345
JO - Sensors and Actuators B: Chemical
JF - Sensors and Actuators B: Chemical
ER -