TY - GEN
T1 - Quantification of extent of muscle-skin shifting by traversal semg analysis using high-density sEMG sensor
AU - Okajima, Shotaro
AU - Ianez, Eduardo
AU - Yamasaki, Hiroshi
AU - Garcia, Alvaro Costa
AU - Alnajjar, Fady S.
AU - Hattori, Noriaki
AU - Shimoda, Shingo
N1 - Publisher Copyright:
© 2019 IEEE.
PY - 2019/9
Y1 - 2019/9
N2 - Surface electromyography(sEMG) measurement has been an essential approach to analyze human behaviors because we can generally consider that sEMG signals represent the muscle activities as the final output of our nerve system. One of the most serious problems for considering sEMG signal as the muscle activity is the shift of the relative position between muscles and skin depending on a posture. The motion of forearm rotation is the prominent example of muscle-skin shifting depending on postural changes. The sEMG signal from a sensor may represent the different muscle activity when the muscle-skin shifting is happened. In this study, we discuss a method to quantify the muscle-skin shift from the sEMG signals in response to the postural changes. We use the high density sEMG sensor that is possible to measure sEMG signal as the potential map. We proposed the computation algorithm to quantify the amount of muscle-skin shifting based on the change of the sEMG signals in response to the postural changes. We conducted the experiments of wrist extension motions under three different forearm postures: forearm pronation, natural posture and forearm supination. Experimental results from three healthy subjects show that we can quantify the extent of muscle-skin shifting as an angle by using proposed algorithm.
AB - Surface electromyography(sEMG) measurement has been an essential approach to analyze human behaviors because we can generally consider that sEMG signals represent the muscle activities as the final output of our nerve system. One of the most serious problems for considering sEMG signal as the muscle activity is the shift of the relative position between muscles and skin depending on a posture. The motion of forearm rotation is the prominent example of muscle-skin shifting depending on postural changes. The sEMG signal from a sensor may represent the different muscle activity when the muscle-skin shifting is happened. In this study, we discuss a method to quantify the muscle-skin shift from the sEMG signals in response to the postural changes. We use the high density sEMG sensor that is possible to measure sEMG signal as the potential map. We proposed the computation algorithm to quantify the amount of muscle-skin shifting based on the change of the sEMG signals in response to the postural changes. We conducted the experiments of wrist extension motions under three different forearm postures: forearm pronation, natural posture and forearm supination. Experimental results from three healthy subjects show that we can quantify the extent of muscle-skin shifting as an angle by using proposed algorithm.
UR - http://www.scopus.com/inward/record.url?scp=85089506392&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85089506392&partnerID=8YFLogxK
U2 - 10.1109/CBS46900.2019.9114488
DO - 10.1109/CBS46900.2019.9114488
M3 - Conference contribution
AN - SCOPUS:85089506392
T3 - 2019 IEEE International Conference on Cyborg and Bionic Systems, CBS 2019
SP - 272
EP - 277
BT - 2019 IEEE International Conference on Cyborg and Bionic Systems, CBS 2019
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2019 IEEE International Conference on Cyborg and Bionic Systems, CBS 2019
Y2 - 18 September 2019 through 20 September 2019
ER -