Thermal control of droplet size in microchannels

Nam Trung Nguyen, Teck Hui Ting, Yitt Fat Yap, Teck Neng Wong, John Chee Kiong Chai, Wee Liat Ong, Junlong Zhou, Say Hwa Tan, Levent Yobas

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper reports an effective method for controlling droplet size in microchannels. The droplet formation process can be controlled precisely using integrated heater and temperature sensor. With a relatively low temperature range from 25°C to 45°C, droplet diameter can be adjusted up to 2.24 times of its original size. That means a droplet volume up to five times of the original value can be adjusted. The low temperature range makes sure that this concept is applicable for droplets containing biological samples.

Original languageEnglish
Title of host publicationProceedings of the 11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, uTAS 2007
EditorsJean-Louis Viovy, Patrick Tabeling, Stephanie Descroix, Laurent Malaquin
PublisherChemical and Biological Microsystems Society
Pages1562-1564
Number of pages3
ISBN (Electronic)9780979806407
Publication statusPublished - 2007
Externally publishedYes
Event11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, uTAS 2007 - Paris, France
Duration: Oct 7 2007Oct 11 2007

Publication series

NameProceedings of the 11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, uTAS 2007

Conference

Conference11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, uTAS 2007
Country/TerritoryFrance
CityParis
Period10/7/0710/11/07

Keywords

  • Active droplet control
  • Droplet-based microfluidics
  • LOC
  • Microdroplet

ASJC Scopus subject areas

  • Chemical Engineering (miscellaneous)
  • Bioengineering

Fingerprint

Dive into the research topics of 'Thermal control of droplet size in microchannels'. Together they form a unique fingerprint.